Products in stock
Stock list updated: 29 Nov 2026, 04:00. Quantities are indicative and change daily. Please enquire to confirm availability.
Showing 12,001–12,050 of 45,998 items
| Image | Stock code | Part number | Description | Manufacturer | Qty | Datasheet |
|---|---|---|---|---|---|---|
| 15M4133-X | NM1-UVR-250S | UNDER VOLTAGE SHUNT RELEASE FOR NM1-225S-400VDetailsUNDER VOLTAGE SHUNT RELEASE |
CHINT | 6 | ||
| 15M4134-X | NM1-UVR-400S | UNDER VOLTAGE SHUNT RELEASE FOR 400V /525VDetailsUNDER VOLTAGE SHUNT RELEASE |
CHINT | 1 | ||
| 15M4136-X | NM1-UVR-800H | UNDER VOLTAGE SHUNT RELEASE FOR NM1-800H-QDetailsUNDER VOLTAGE SHUNT RELEASE |
CHINT | 1 | ||
| 15M4137-X | NM1-VDH-1250H | VARIABLE DEPTH HANDLE FOR NM1-1250H | CHINT | 1 | ||
| 15M4139-X | NM1-VDH-250S | VARIABLE DEPTH HANDLE FOR NM1-225S | CHINT | 1 | ||
| 15M4140-X | NM1-VDH-400S | VARIABLE DEPTH DOOR INTERLOCK HANDLE | CHINT | 3 | ||
| 15M4142-X | NM8-125S-100A | MCCB ADJUST 3P (80-100A)DetailsMOLDED CASE CIRCUIT BREAKER |
CHINT | 1 | ||
| 15M4143-X | NM8-125S-125A | MCCB ADJUST 125A 3P 50KA (100/125A)DetailsMOLDED CASE CIRCUIT BREAKER |
CHINT | 4 | ||
| 15M4146-X | NM8-250S-250A | MCCB ADJUST 250A 3P 50KA (200/250A)DetailsMOLDED CASE CIRCUIT BREAKER ADJUSTABLE |
CHINT | 1 | ||
| 15M4147-X | NM8-400S-315A | MCCB CIRCUIT BREAKER ADJUST 315A 3P 50KA (252-315A)DetailsMOLDED CASE CIRCUIT BREAKER |
CHINT | 1 | ||
| 15M4150 | ML2585G01-109 | SIL SOCKET STR HOUSED P=2.54 9-WDetails9 WAY SOCKET / FEMALE HEADER / STRAIGHT / 2.54 PITCH, HEIGHT=8.6, 3MM FLAT PINS |
MORECRAFTS | 355 | ||
| 15M4151-X | NM8-VDH-250S | VARIABLE DEPTH HANDLE FOR NM8-250SDetailsVARIABLE DEPTH HANDLE |
CHINT | 3 | ||
| 15M4152-X | NM8-VDH-400S | VARIABLE DEPTH HANDLE FOR NM8-400SDetailsVARIABLE DEPTH HANDLE |
CHINT | 1 | ||
| 15M4153-X | NM8-VDH-630S | VARIABLE DEPTH HANDLE FOR NM8-630S 300MMDetailsVARIABLE DEPTH HANDLE |
CHINT | 2 | ||
| 15M4155-X | NP2-BD23 | ROTARY SELECTOR SWITCH 22MM 2POS, 2NODetailsPANEL MOUNT ROTARY SELECTOR SWITCH 22MM 2-POSITIONS, 2 NORMALLY OPEN CONTACTS / 4NO |
CHINT | 20 | ||
| 15M4156-X | NP2-BD33 | ROTARY SELECTOR SWITCH 22MM 3POS, NO-OFF-ONDetailsPANEL MOUNT ROTARY SELECTOR SWITCH 22MM 3-POSITIONS, 2 NORMALLY OPEN CONTACTS. |
CHINT | 1 | ||
| 15M4158 | LTY-M8DZ-S | LED HOLDER 5mm CHROME FLAT TYPEDetails5MM CHROMED SURFACE MOUNT LED HOLDER, PANEL MOUNT, MOUNTING HOLE DIAMETER=8MM |
VS | 55 | – | |
| 15M4159-X | NP9-22/2 | D/R MOUNT PUSH-BUTTON RED 2NO+2NCDetailsRED, DIN RAIL MOUNT PUSH BUTTON |
CHINT | 2 | – | |
| 15M4160-X | NQ2-15/P-400-13 | DOL STARTER 400V 9-13ADetailsDIRECT ONLINE STARTER SWITCH FOR MOTORS, PROTECTS FROM OVERLOAD AND PHASE FAILURE, |
CHINT | 5 | ||
| 15M4161-X | NQ2-15P/2-40018 | DOL STARTER 18A 400V METALDetailsDIRECT ONLINE STARTER SWITCH FOR MOTORS, PROTECTS FROM OVERLOAD AND PHASE FAILURE, |
CHINT | 5 | ||
| 15M4162-X | NQ3-5.5P-220V-1-1.6-Q | DOL - STARTER 220V 1.0-1.6A 0.55KWDetailsDIRECT ONLINE STARTER SWITCH FOR MOTORS, PROTECTS FROM OVERLOAD AND PHASE FAILURE, |
CHINT | 5 | ||
| 15M4164-X | NQ3-5.5P-13-Q | DOL STARTER 9-13A O/L 400VDetailsDIRECT ONLINE STARTER SWITCH FOR MOTORS, PROTECTS FROM OVERLOAD AND PHASE FAILURE, |
CHINT | 1 | ||
| 15M4165-X | NQ3-5.5P-2.5-M | DOL STARTER 1.6- 2.5 240VDetailsDIRECT ONLINE STARTER SWITCH FOR MOTORS, PROTECTS FROM OVERLOAD AND PHASE FAILURE, |
CHINT | 10 | ||
| 15M4166-X | NQ3-5.5P-4-Q | DOL STARTER 400V 2.5-4.0A- 1.5KWDetailsDIRECT ONLINE STARTER SWITCH FOR MOTORS, PROTECTS FROM OVERLOAD AND PHASE FAILURE, |
CHINT | 11 | ||
| 15M4167-X | NQ3-5.5P-8-Q | DOL STARTER - 3KW 240V 5.5 - 8A O/LDetailsDIRECT ONLINE STARTER SWITCH FOR MOTORS, PROTECTS FROM OVERLOAD AND PHASE FAILURE, |
CHINT | 9 | ||
| 15M4168-X | NR2-150-120 | THERMAL OVERLOAD PROTECTION RELAY 95-120ADetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 1 | ||
| 15M4169-X | NR2-150-150 | THERMAL OVERLOAD PROTECTION RELAY 110-150 AMPDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 4 | ||
| 15M4170-X | NR2-200-160A | THERMAL OVERLOAD PROTECTION RELAY 100-160AMP 75KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 2 | ||
| 15M4171-X | NR2-200-200 | THERMAL OVERLOAD PROTECTION RELAY 125- 200ADetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 2 | ||
| 15M4173-X | NR2-25-0.4 | THERMAL OVERLOAD PROTECTION RELAY 0.25- 0.4 A 0.09KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 20 | ||
| 15M4174-X | NR2-25-0.6 | THERMAL OVERLOAD PROTECTION RELAY 0.40-0.63A 0.2KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 10 | ||
| 15M4175-X | NR2-25-1.0 | THERMAL OVERLOAD PROTECTION RELAY 0.63-1A 0.37KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 39 | ||
| 15M4177-X | NR2-25-10 | THERMAL OVERLOAD PROTECTION RELAY 7-10A 4KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 29 | ||
| 15M4178-X | NR2-25-13 | THERMAL OVERLOAD PROTECTION RELAY 9-13A 5.5KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 38 | ||
| 15M4180-X | NR2-25-2.5 | THERMAL OVERLOAD PROTECTION RELAY 1.6 - 2.5A 0.75KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 84 | ||
| 15M4181-X | NR2-25-25 | THERMAL OVERLOAD PROTECTION RELAY 17-25A 11KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 42 | ||
| 15M4182-X | NR2-25-2.5-4A | THERMAL OVERLOAD PROTECTION RELAY 2.5-4.0A 1.5KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 1 | ||
| 15M4183-X | NR2-25-4-6A | THERMAL OVERLOAD PROTECTION RELAY 4.0-6.0A 2.2KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 13 | ||
| 15M4184-X | NR2-25-5.5-8A | THERMAL OVERLOAD PROTECTION RELAY 5.5-8.0A 3KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 96 | ||
| 15M4186-X | NR2-36-32 | THERMAL OVERLOAD PROTECTION RELAY 23-32A 15KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 18 | ||
| 15M4187-X | NR2-36-36 | THERMAL OVERLOAD PROTECTION RELAY 28-36A 18.5KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 4 | ||
| 15M4188-X | NR2-630-630A | THERMAL OVERLOAD PROTECTION RELAY 400-630ADetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 1 | ||
| 15M4189-X | NR2-93 | THERMAL OVERLOAD PROTECTION RELAY NR2-93DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 3 | ||
| 15M4190-X | NR2-93-40 | THERMAL OVERLOAD PROTECTION RELAY 30-40A 18.5KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 2 | ||
| 15M4192-X | NR2-93 48-65A | THERMAL OVERLOAD PROTECTION RELAY 48-65A 30KW 268148DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 1 | ||
| 15M4193-X | NR2-93 55-70A | THERMAL OVERLOAD PROTECTION RELAY 55-70A 268120DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 11 | ||
| 15M4195-X | NR2-93-93 | THERMAL OVERLOAD PROTECTION RELAY 80-93A 45KWDetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 3 | ||
| 15M4196-X | NS2-X25-0.63-1.0A | MANUAL MOTOR STARTER 0.63-1ADetailsALTERNATING CURRENT MOTOR STARTER |
CHINT | 19 | ||
| 15M4197-X | NS2-25-0.63A | MANUAL MOTOR STARTER 0.4-0.63A | CHINT | 5 | ||
| 15M4198-X | 200823 | TEST CLIP MODULE 8W DIL/DIP TO SMD-SOIC/SOP8DetailsSOP8 / SOIC8 TEST CLIP MODULE WITH CABLE FOR EEPROM 93CXX / 25CXX / 24CXX FOR IN CIRCUIT PROGRAMMING |
EIE | 10 | – |
